ACTO GmbH

ACTOSED® PA 

Concentrated High-Level Disinfectant for Endoscopes and Medical Instruments

Properties

ACTOSED® PA  provides the user with fast, efficient and safe handling and is one of the best choices for high- level disinfection of medical instruments and endoscopes. The aldehyde-free formulation makes the product safer for the environment and users.

ACTOSED® PA  is suitable for the pre-cleaning and disinfection of surgical instruments made from stainless steel, dentistry instruments, endoscopes, anesthesia equipment, and the materials, which are resistant or not resistant to heat, including Minimally Invasive Surgical (MIS) instruments by manually or in ultrasonic washing machines.

Chemical composition​

100 g contains: 0.59 g N,N bis (3-aminopropyl) dodecylamine, 0.72 g didecylmethylpolyoxyethyl ammonium propionate and auxiliary substances.

Microbiological Activity​

Microbiological ActivityTest MethodConcentrationEffect Time
BactericidalEN 14561 / EN 137271 %10 min.
FungicidalEN 145621 %10 min.
Tuberculocidal, MycobactericidalEN 145631 %10 min.
Virucidal (Adeno. Polio, MNV)EN 144761 %10 min.
SporicidalEN 137043 %10 min.

Material Compatibility:

ACTOSED® PA is compatible with fiexible and rigid endoscopes, anesthesia materials, surgical instruments made of stainless steel, thermoplastics and elastomer, Product is not suitable for instruments with deteriorated coating nor instruments which are made of copper, brass, anodized aluminum material. The product is üşed in the widely-known endoscope brands such as Wolf Storz, Fujinon, Pentax, Olympus.

Method Of Use:

Before using ACTOSED® PA, clean the instrument surfaces and canals with a suitable enzymatic cleaner. (We recommend ACTOCLEAN® PERFECT). After cleaning, rinse and dry the instruments.

First fiil the disinfection bath with water (at room temperature), add the product at an appropriate amount, wait for 10-15 seconds. Make sure that ali instruments and all canals come into contact with the solution during application. The lid of the disinfectant bath must be kept closed during üşe, The non  contaminated solution is stable for 7 days. The minimum effective concentration (MEC) should be checked with the test strips. İf the color in test strips changes, the solution should be changed. After the recommended contact time, the medical devices should be rinsed with water of at least drinking water quality and dried.

Concentration of Use

Concentration RatioAmount of WaterProduct Quantity
1 %990 ml10 ml
3 %970 ml30 ml (1 Pump)

Packaging​

Article-No.UnitPieces in Box
01.9305.22 L9
01.9305.55 L4
14.4154.25Test Strip – Pack of 25 pcs 

Downloads